Fanuc Servo Alarm 1 - for general servos

FANUC Alarm Codes >> FANUC Servo Alarms >> Servo Alarm 01, 1

Model Description
C Series Fanuc Servo Amplifier Alarms (6066) DC voltage of the main circuit power supply is abnormally high.
Fanuc Servo Amplifer Alarms (6089) DC voltage of the main circuit power supply is abnormally high.
Fanuc Servo Amplifer Alarms (6090) DC voltage of the main circuit power supply is abnormally high.
Alpha Fanuc Servo Amplifer Alarms (6071, 6079, 6080, 6096) Internal cooling circuit faulty
aiS SVM 6114, 6120 Internal cooling circuit faulty
Servo Amplifer Alarms (6240) Internal cooling circuit faulty
ai B Power Supply Alarms (6200, 6202) Overcurrent flowed into the input of the main circuit. Input supply voltage imbalance, IGBT defective. (PSM-15 to PSM-55)
Fanuc  Alpha i Power Supply Alarms (6110, 6115, 6140) Overcurrent flowed into the input of the main circuit. Input supply voltage imbalance, IGBT defective. (PSM-15 to PSM-55)
Beta Fanuc Servo Amplifer Alarms (6093) The battery voltage of the absolute pulse coder is low. (warning)
Fanuc Alpha Power Supply Alarms (6077, 6087) The main circuit power module (IPM) has detected an overload, overcurrent, or control supply voltage decrease, overcurrent, or control supply voltage decrease. Internal cooling circuit failure, Overload, Input supply voltage imbalance, IPM failure, or control supply voltage decrease of the power module.
ai B Power Supply Alarms (6200, 6202) The main circuit power module (IPM) has detected an overload, overcurrent, or control supply voltage decrease, overcurrent, or control supply voltage decrease. Internal cooling circuit failure, Overload, Input supply voltage imbalance, IPM failure, or control supply voltage decrease of the power module. (PSM-5.5 to PSM-11)
Fanuc  Alpha i Power Supply Alarms (6110, 6115, 6140) The main circuit power module (IPM) has detected an overload, overcurrent, or control supply voltage decrease, overcurrent, or control supply voltage decrease. Internal cooling circuit failure, Overload, Input supply voltage imbalance, IPM failure, or control supply voltage decrease of the power module. (PSM-5.5 to PSM-11)

 

 

 


Contact Tri Star CNC Services


Nationwide FANUC Servo Error Troubleshooting, Repairs & Replacement Service

Give Tri Star CNC a call and we’ll help you determine the source of the FANUC servo 01, 1 error and find solutions ASAP. We offer FREE phone support (call 815-578-9145 now), competitive repair pricing, or quick turnaround on a replacement component from our exchange stock if necessary. If you need on-site support we can point you in the right direction through our field service network.

FANUC-GE Parts Exchange & Repair Warranty Information

Exchange FANUC parts and repaired parts include a 1-year warranty. Tri Star CNC, LLC warrants the COMPLETE ASSEMBLY REPAIR – not just the parts and labor.

Get more details on our FANUC warranty and please contact us for further CNC machine support.

 

Contact Us

For parts repair or replacement, please fill out the form below and we’ll get back to you as soon as possible.

upload pdf

* Indicates a Required Field
Call now for FREE phone support
FREE Phone Support
815-578-9145