LIMITED TIME ONLY for new customers: 15% off your first repair order!

Part Details

A06B-6055-H108#H539 SPINDLE AMP AC SP-2VH/20000RPM

FANUC parts >> A06B-6055-H108#H539 SPINDLE AMP AC SP-2VH/20000RPM

Part Name: SPINDLE AMP AC SP-2VH/20000RPM

Part Number: A06B-6055-H108#H539

Contact Us

For parts repair or replacement, please fill out the form below and we’ll get back to you as soon as possible.

upload pdf

* Indicates a Required Field

Exchange Price

$5550

OUT OF STOCK
Non return of a repairable exchange part within 15 days will result in an additional invoice for the above exchange price.

Repair Price

$3519

Turnaround times for standard repairs are based on workload. Please contact Tri Star CNC services for emergency repair requirements.
Please contact Tri Star CNC Services to place an order.

SPINDLE AMP AC SP-2VH/20000RPM

Imagine your spindle amplifier fizzles and stops working. Your A06B-6055-H108 is now out of commission and productivity grinds to a halt. Who are you going to call? If you want the best, you're calling Tri Star CNC Services.

Tri Star is the best name in the market for FANUC and GE FANUC parts and repairs. Specializing on the component level repair of controls, servo drives, spindle amplifiers, power supplies, I/O printed circuit boards and other FANUC control related parts. Our combined experience of +90 years translates into CNC machines running smoothly at the lowest long term cost to you.

At Tri Star our number one priority is timely and effective repair of malfunctioning CNC machines. Unlike other services and manufacturers we consider controls a part of a machine. We take the malfunctioning part back to our facility and fully test it on closed loop control systems. If no problem is found then you will be charged only a nominal clean and test fee. Our test benches support the system 6 control all the way through to the 16i, 18i, 21i and 0i series controls. This includes the power supplies, servos and spindle units for these systems too.

If we need to, we can custom engineer replacement FANUC parts at a lower cost than the OEM parts. One more way Tri Star can bring value to your business with our quality-driven team. So for the best name in CNC Services, contact Tri Star.

Error codes & alarms

When a FANUC spindle amp alarm is thrown chances are you'll need support from professionals experienced in FANUC component repairs. Give us a call - phone support is FREE and we'll clearly define your options for parts repair or replacement:

Alarm CodeDescription
01 Spindle motor over temp
02 Actual motor speed is largely deviated from the commanded speed.
03 DC link fuse has blown
04 Detected that the 3-phase input to the main circuit of the PSM has an open phase.
07 The motor rotates at a speed exceeding 115% (standard setting) of the maximum allowable speed.
09 Temperature of the heat sink of the SPM main circuit has risen to the set value.
10 Input power voltage dropped.
11 PSM detected that the DC link voltage was excessively high.
12 Excessively large current flowed into the DC link of the main circuit.
13 Memory inside the CPU is faulty.
15 Spindle switching operation sequence was not executed correctly.
16 The memory (RAM) is faulty.
17 NVRAM is faulty.
19 The offset voltage of the phase U current detection circuit is excessively high.
20 The offset voltage of the phase V current detection circuit is excessively high.
24 The power to the CNC is turned off. (This symptom does not represent an error.) Serial communication data transferred between the CNC and spindle amplifier module contains an error.
25 Serial communication between the CNC and spindle amplifier module stopped.
26 The sensor signal (for speed control) for Cs contour control has an error.
27 The sensor signal (position coder signal) for position control is abnormal.
28 The sensor signal (for position control) for Cs contour control is abnormal.
29 An excessive load (standard setting: load meter reading of 9 V) has been applied continuously for a certain period (standard setting: 30 seconds).
30 An excessively large current is detected at the input of the 3-phase main circuit of the PSM.
31 The motor failed to rotate as specified, and has stopped or is rotating at a very low speed.
32 LSI memory for serial communication is abnormal. A check is made when the power is turned on.
33 The PSM could not be charged within a specified time. PSM input has an open phase.
34 Parameter data outside the specifiable range was set.
35 The gear ratio set in a parameter exceeds the value range allowable for internal processing. This alarm is issued with a parameter related to orientation of magnetic sensor type.
36 Error counter overflowed.
37 After emergency stop signal input, the motor is accelerated without being decelerated. This alarm is issued also when the motor is not deactivated (the motor is not decelerated completely) when the acceleration/deceleration time (initial parameter setting: 10 seconds) has elapsed after emergency stop signal input.
39 The position where the one-rotation signal for Cs contour control is generated is incorrect. This alarm is not issued when the parameter indicated below is not set.
40 The one-rotation signal for Cs contour control is not generated.
41 The position where the one-rotation signal of the α position coder, BZ sensor, MZ sensor, α position coder S is incorrect.
47 The count value of α position coder signal pulses is abnormal. The pulse count value of the MZ sensor or BZ sensor is abnormal.

Contact the CNC repair technicians at Tri Star for more information on A06B-6055-H108# SP-15P spindle amp repair services.

Parts & Repair Warranty Information

Exchange parts and repaired parts include a 1-year warranty. Tri Star CNC, LLC warrants the COMPLETE ASSEMBLY REPAIR – not just the parts and labor.

Get more details on our warranty and please contact us for further support.

Contact Us

For parts repair or replacement, please fill out the form below and we’ll get back to you as soon as possible.

upload pdf

* Indicates a Required Field
Call now for FREE phone support
FREE Phone Support
815-578-9145