SPINDLE AMP AC SP-15P

Anyone who's been in the CNC machining business longer than a week knows how temperamental spindle amps can be after a few years of hard use. Even quality-built units from GE and GE FANUC will eventually fail in one way or another. When they do, turn to Tri Star CNC Services to get you up and running again.

At Tri Star, all repair work is done in-house by our experienced technicians. We treat every job as a priority and work quickly to get your malfunctioning unit repaired and back to your shop. Your A06B-6055-H108# SP-15P spindle amp will be repaired using OEM or better quality parts. If necessary, we'll even custom engineer replacement parts.

While we have your unit, we'll give it a thorough cleaning and replace any electrical components known to have a high failure rate - at no additional cost to you. Before sending your unit back, we'll test it on a closed loop system to ensure it's operating to specification. Then, we'll back our work with a one-year parts and labor warranty on the complete assembly. It's all part of our above and beyond service.

With over 90 years of combined experience, a reputation for quality work at great prices and an unmatched warranty, we are proud of our growing reputation as THE alternative source for GE FANUC and FANUC parts and repairs. Try us just once and you'll see.

Error codes & alarms

When a FANUC spindle amp alarm is thrown chances are you'll need support from professionals experienced in FANUC component repairs. Give us a call - phone support is FREE and we'll clearly define your options for parts repair or replacement:

Alarm CodeDescription
01 Spindle motor over temp
02 Actual motor speed is largely deviated from the commanded speed.
03 DC link fuse has blown
04 Detected that the 3-phase input to the main circuit of the PSM has an open phase.
07 The motor rotates at a speed exceeding 115% (standard setting) of the maximum allowable speed.
09 Temperature of the heat sink of the SPM main circuit has risen to the set value.
10 Input power voltage dropped.
11 PSM detected that the DC link voltage was excessively high.
12 Excessively large current flowed into the DC link of the main circuit.
13 Memory inside the CPU is faulty.
15 Spindle switching operation sequence was not executed correctly.
16 The memory (RAM) is faulty.
17 NVRAM is faulty.
19 The offset voltage of the phase U current detection circuit is excessively high.
20 The offset voltage of the phase V current detection circuit is excessively high.
24 The power to the CNC is turned off. (This symptom does not represent an error.) Serial communication data transferred between the CNC and spindle amplifier module contains an error.
25 Serial communication between the CNC and spindle amplifier module stopped.
26 The sensor signal (for speed control) for Cs contour control has an error.
27 The sensor signal (position coder signal) for position control is abnormal.
28 The sensor signal (for position control) for Cs contour control is abnormal.
29 An excessive load (standard setting: load meter reading of 9 V) has been applied continuously for a certain period (standard setting: 30 seconds).
30 An excessively large current is detected at the input of the 3-phase main circuit of the PSM.
31 The motor failed to rotate as specified, and has stopped or is rotating at a very low speed.
32 LSI memory for serial communication is abnormal. A check is made when the power is turned on.
33 The PSM could not be charged within a specified time. PSM input has an open phase.
34 Parameter data outside the specifiable range was set.
35 The gear ratio set in a parameter exceeds the value range allowable for internal processing. This alarm is issued with a parameter related to orientation of magnetic sensor type.
36 Error counter overflowed.
37 After emergency stop signal input, the motor is accelerated without being decelerated. This alarm is issued also when the motor is not deactivated (the motor is not decelerated completely) when the acceleration/deceleration time (initial parameter setting: 10 seconds) has elapsed after emergency stop signal input.
39 The position where the one-rotation signal for Cs contour control is generated is incorrect. This alarm is not issued when the parameter indicated below is not set.
40 The one-rotation signal for Cs contour control is not generated.
41 The position where the one-rotation signal of the α position coder, BZ sensor, MZ sensor, α position coder S is incorrect.
47 The count value of α position coder signal pulses is abnormal. The pulse count value of the MZ sensor or BZ sensor is abnormal.

Contact the CNC repair technicians at Tri Star for more information on A06B-6055-H108# SP-15P spindle amp repair services.

Parts & Repair Warranty Information

Exchange parts and repaired parts include a 1-year warranty. Tri Star CNC, LLC warrants the COMPLETE ASSEMBLY REPAIR – not just the parts and labor.

Get more details on our warranty and please contact us for further support.

Contact Us

For parts repair or replacement, please fill out the form below and we’ll get back to you as soon as possible.

upload pdf

* Indicates a Required Field
Call now for FREE phone support
FREE Phone Support
815-578-9145