SPINDLE AMP AC SP-8/6000RPM

See if this sounds familiar: Things were going great until your A06B-6055-H108#H514 Spindle Amp started acting up. Or not acting at all. But now you've found Tri Star CNC Services and your day is about to get a lot better.

Tri Star CNC Services specializes in the repair of sophisticated FANUC and GE FANUC spindle amps and other CNC machine parts. In fact, one of our founders spent 15 years at FANUC and was the brains behind many of their test benches. So, we know our way around spindle amps and the like.

Our experienced repair technicians will thoroughly diagnose your AC SP-8 6000RPM spindle amp and use OEM or better parts to bring it back to original specifications. While we're at it, we'll replace any electrical components known to have a high failure rate and give your unit a good cleaning - at no extra charge. Then we back up our work with a one-year parts and repair warranty that covers the entire assembly repair - not just the parts and labor covered by most repair companies. You'll also be eligible for free technical phone support from our FANUC gurus.

We treat every repair as a priority. You may also opt to trade your nonfunctioning spindle amp unit in on a fully refurbished unit, provided we have one in stock.

At Tri Star CNC Services, we are all about doing whatever it takes to help you stay in business and keep your operating costs down. Amazingly, we do it without outsourcing our repair work. Everything is done in-house. Shop around if you want. We're confident you'll find Tri Star CNC Services offers the best value for FANUC and GE FANUC repair work.

Error codes & alarms

When a FANUC spindle amp alarm is thrown chances are you'll need support from professionals experienced in FANUC component repairs. Give us a call - phone support is FREE and we'll clearly define your options for parts repair or replacement:

Alarm CodeDescription
01 Spindle motor over temp
02 Actual motor speed is largely deviated from the commanded speed.
03 DC link fuse has blown
04 Detected that the 3-phase input to the main circuit of the PSM has an open phase.
07 The motor rotates at a speed exceeding 115% (standard setting) of the maximum allowable speed.
09 Temperature of the heat sink of the SPM main circuit has risen to the set value.
10 Input power voltage dropped.
11 PSM detected that the DC link voltage was excessively high.
12 Excessively large current flowed into the DC link of the main circuit.
13 Memory inside the CPU is faulty.
15 Spindle switching operation sequence was not executed correctly.
16 The memory (RAM) is faulty.
17 NVRAM is faulty.
19 The offset voltage of the phase U current detection circuit is excessively high.
20 The offset voltage of the phase V current detection circuit is excessively high.
24 The power to the CNC is turned off. (This symptom does not represent an error.) Serial communication data transferred between the CNC and spindle amplifier module contains an error.
25 Serial communication between the CNC and spindle amplifier module stopped.
26 The sensor signal (for speed control) for Cs contour control has an error.
27 The sensor signal (position coder signal) for position control is abnormal.
28 The sensor signal (for position control) for Cs contour control is abnormal.
29 An excessive load (standard setting: load meter reading of 9 V) has been applied continuously for a certain period (standard setting: 30 seconds).
30 An excessively large current is detected at the input of the 3-phase main circuit of the PSM.
31 The motor failed to rotate as specified, and has stopped or is rotating at a very low speed.
32 LSI memory for serial communication is abnormal. A check is made when the power is turned on.
33 The PSM could not be charged within a specified time. PSM input has an open phase.
34 Parameter data outside the specifiable range was set.
35 The gear ratio set in a parameter exceeds the value range allowable for internal processing. This alarm is issued with a parameter related to orientation of magnetic sensor type.
36 Error counter overflowed.
37 After emergency stop signal input, the motor is accelerated without being decelerated. This alarm is issued also when the motor is not deactivated (the motor is not decelerated completely) when the acceleration/deceleration time (initial parameter setting: 10 seconds) has elapsed after emergency stop signal input.
39 The position where the one-rotation signal for Cs contour control is generated is incorrect. This alarm is not issued when the parameter indicated below is not set.
40 The one-rotation signal for Cs contour control is not generated.
41 The position where the one-rotation signal of the α position coder, BZ sensor, MZ sensor, α position coder S is incorrect.
47 The count value of α position coder signal pulses is abnormal. The pulse count value of the MZ sensor or BZ sensor is abnormal.

Contact the CNC repair technicians at Tri Star for more information on A06B-6055-H108#H514 Spindle Amp repair services.

Parts & Repair Warranty Information

Exchange parts and repaired parts include a 1-year warranty. Tri Star CNC, LLC warrants the COMPLETE ASSEMBLY REPAIR – not just the parts and labor.

Get more details on our warranty and please contact us for further support.

Contact Us

For parts repair or replacement, please fill out the form below and we’ll get back to you as soon as possible.

upload pdf

* Indicates a Required Field
Call now for FREE phone support
FREE Phone Support
815-578-9145