LIMITED TIME ONLY for new customers: 15% off your first repair order!

Part Details

A06B-6111-H002#H550 GE FANUC SPINDLE AMP MODULE SPM-2.2I

FANUC parts >> A06B-6111-H002#H550 GE FANUC SPINDLE AMP MODULE SPM-2.2I

Part Name: GE FANUC SPINDLE AMP MODULE SPM-2.2I

Part Number: A06B-6111-H002#H550

Contact Us

For parts repair or replacement, please fill out the form below and we’ll get back to you as soon as possible.

upload pdf

* Indicates a Required Field

Exchange Price

$1959

OUT OF STOCK
Non return of a repairable exchange part within 15 days will result in an additional invoice for the above exchange price.

Repair Price

$1440

Turnaround times for standard repairs are based on workload. Please contact Tri Star CNC services for emergency repair requirements.
Please contact Tri Star CNC Services to place an order.

A06B-6111-H002#H550 GE FANUC SPINDLE AMP MODULE SPM-2.2i

The A06B-6111-H002#H550 SPM 2.2i is part of the i-series with a 200v Fanuc alpha spindle power amplifier module drive. The A06B-6111-H002#H550 is a 2.2Kw power alpha spindle amplifier drive, commonly used in small CNC machining centers. Whether the Fanuc spindle amp is malfunctioning and you need a spindle drive repair or you’re looking for another part, Tri Star CNC Services can help get your system back up and running to keep production going.

We offer FREE over the phone technical support to resolve the issue or determine if your part must be sent in for repairs. Our experienced Fanuc CNC specialists will test your damaged or malfunctioning A06B-6111-H002#H550 SPM 2.2i on a closed loop system in our own shop. We don’t outsource any of our services, so we can guarantee you fast and reliable service every time.

Info on FANUC spindle amplifier modules available from our exchange stock.

We’ll determine whether your part is fixable or beyond repair. Tri Star CNC Services offers credit for your non-functioning unit towards a refurbished part in our Fanuc parts exchange stock.

Error codes & alarms

When a FANUC spindle amp alarm is thrown chances are you'll need support from professionals experienced in FANUC component repairs. Give us a call - phone support is FREE and we'll clearly define your options for parts repair or replacement:

Alarm CodeDescription
- (dash) Unit is not ready  or not commanded to run.
01 Spindle motor over temp
02 Actual motor speed is largely deviated from the commanded speed.
03 DC link fuse has blown
04 Detected that the 3-phase input to the main circuit of the PSM has an open phase.
06 The temerature sensor is abnormal in the motor, or the temperature sensor cable is broken.
07 The motor rotates at a speed exceeding 115% (standard setting) of the maximum allowable speed.
09 Temperature of the heat sink of the SPM main circuit has risen to the set value.
11 PSM detected that the DC link voltage was excessively high.
12 Excessively large current flowed into the DC link of the main circuit.
15 Spindle switching operation sequence was not executed correctly.
18 Program sum check error
19 The offset voltage of the phase U current detection circuit is excessively high.
20 The offset voltage of the phase V current detection circuit is excessively high.
21 Position sensor polarity setting incorrect
24 The power to the CNC is turned off. (This symptom does not represent an error.) Serial communication data transferred between the CNC and spindle amplifier module contains an error.
27 The sensor signal (position coder signal) for position control is abnormal.
29 An excessive load (standard setting: load meter reading of 9 V) has been applied continuously for a certain period (standard setting: 30 seconds).
30 An excessively large current is detected at the input of the 3-phase main circuit of the PSM.
31 The motor failed to rotate as specified, and has stopped or is rotating at a very low speed.
32 LSI memory for serial communication is abnormal. A check is made when the power is turned on.
33 The PSM could not be charged within a specified time. PSM input has an open phase.
34 Parameter data outside the specifiable range was set.
35 The gear ratio set in a parameter exceeds the value range allowable for internal processing. This alarm is issued with a parameter related to orientation of magnetic sensor type.
36 Error counter overflowed.
37 After emergency stop signal input, the motor is accelerated without being decelerated. This alarm is issued also when the motor is not deactivated (the motor is not decelerated completely) when the acceleration/deceleration time (initial parameter setting: 10 seconds) has elapsed after emergency stop signal input.
41 The position where the one-rotation signal of the α position coder, BZ sensor, MZ sensor, α position coder S is incorrect.
42  The one-rotation signal of the α position coder, BZ sensor, MZ sensor, α position coder S is not generated.
46 The one-rotation signal of the position coder cannot be detected normally during thread cutting.
47 The count value of α position coder signal pulses is abnormal. The pulse count value of the MZ sensor or BZ sensor is abnormal.
50 A value obtained by internal calculation in spindle synchronization exceeded the allowable range.
51 The PSM detected that the DC link voltage was excessively low.
52 The synchronization signal (ITP) in communication data transferred to and from the CNC stopped.
53 The synchronization signal (ITP) in communication data transferred to and from the CNC stopped.
54 A large current flowing in the motor for a long time was detected.
55 In spindle switching control or output switching control, a mismatch between the switching request signal (SPSL or RSL) and the power line state check signal (MCFN, MFNHG, RCH, or RCHHG) continues during motor activation.
56 Internal cooling circuit faulty.
57 The temperature of the regenerative resistance of the PSM (resistance regenerative type) is excessively high. The PSM is faulty.
58 The temperature of the main circuit-cooling fan of the PSM is abnormally high.
59 The internal cooling fan of the PSM stopped.
66 Error occurred during communication (connector JX4) between spindle and amplifier.
69 This alarm can be issued only when Dual Check Safety is in use. The alarm occurs if, in safety signal mode C (a guard open request was entered to open the guard), the spindle motor rotation speed exceeds entered to open the guard), the spindle motor rotation speed exceeds the safety speed.
70 This alarm can be issued only when Dual Check Safety is in use. The spindle amplifier connection status does not match the hardware setting.
71 This alarm can be issued only when Dual Check Safety is in use. A safety parameter error occurred.
72 This alarm can be issued only when Dual Check Safety is in use. The result of the spindle amplifier speed check does not match the result of the CNC speed check.
73 The signal of the motor sensor is disconnected.
74 This alarm can be issued only when Dual Check Safety is in use. The CPU test failed to end normally.
75 This alarm can be issued only when Dual Check Safety is in use. An error occurred in the CRC test.
76 This alarm can be issued only when Dual Check Safety is in use. The spindle safety function has not been executed.
77 This alarm can be issued only when Dual Check Safety is in use. The result of the spindle amplifier axis number check does not match the result of the CNC axis number check.
78 This alarm can be issued only when Dual Check Safety is in use. The result of spindle amplifier safety parameter check does not match the result of the CNC safety parameter check.
79 This alarm can be issued only when Dual Check Safety is in use. An abnormal operation was detected in the initial test.
80 An alarm was generated on the other spindle amplifier.
81 The position where the one-rotation signal of the motor sensor is generated is incorrect.
82 The one-rotation signal of the motor sensor is not generated.
83 The SPM checks the pulse counts of phases A and B each time a one rotation
signal is generated. The alarm is issued when a pulse count beyond the specified range is detected.
84 The spindle sensor signal was disconnected. Refer to Alarm Code 73 for this alarm trouble shooting.
85 The one-rotation signal of the spindle sensor occurred in an incorrect location. Refer to Alarm Code 81 for this alarm trouble shooting.
86 No spindle sensor one-rotation signal occurred. Refer to Alarm Code 82 for this alarm trouble shooting.
87 A spindle sensor signal is abnormal. Refer to Alarm Code 83 for this alarm trouble shooting.
88 External cooling circuit faulty.
A, A1, A2 Program ROM error
b0 An error occurred in communication between amplifier modules (SPM, SVM, and PSM).
b1 Converter: control power supply low voltage
b2 Converter: excessive regenerative power
b3 Converter: cooling fan stopped of the radiator
C0, C1, C2 An error occurred in serial communication data between the CNC and spindle amplifier module.
C3 In spindle switching, a mismatch is found between the switching request signal (SPSL) and the internal status of the motor/spindle sensor signal switching circuit (submodule SW).

Contact Tri Star CNC Services for information on exchanges or repairs.

Parts & Repair Warranty Information

Exchange parts and repaired parts include a 1-year warranty. Tri Star CNC, LLC warrants the COMPLETE ASSEMBLY REPAIR – not just the parts and labor.

Get more details on our warranty and please contact us for further support.

Contact Us

For parts repair or replacement, please fill out the form below and we’ll get back to you as soon as possible.

upload pdf

* Indicates a Required Field
Call now for FREE phone support
FREE Phone Support
815-578-9145