A06B-6102-H211 SPM-11 FANUC Spindle Amplifier Module

The A06B-6102-H211 SPM-11 is a FANUC spindle power amplifier drive highly utilized in CNC machining centers. The A06B-6102-H211 SPM-11 spindle amp drive is the last non HV generation drive preceding the I series spindle power amplifiers. The skilled FANUC repair service technicians at Tri Star CNC Services, LLC provide unrivaled FANUC repairs for your A06B-6102-H211 SPM-11 alpha spindle power amplifier module.

Alarm & error codes

When a FANUC alpha spindle amplifier alarm is thrown chances are you'll need support from professionals experienced in FANUC component repairs. Give us a call - phone support is FREE and we'll clearly define your options for parts repair or replacement:

Alarm CodeDescription
- (dash) Unit is not ready or not commanded to run.
0, 00 Amplifier is ready (normal operating state)
A, A0 SPM control program is not operating.
A1, A2 Error was detected in SPM control program processing.
A3 Error was detected in the clock of the SPM control PCB.
A4 Parity error was detected in the SRAM on the SPM control PCB
01 Spindle motor over temp
02 Actual motor speed is largely deviated from the commanded speed.
03 DC link fuse has blown.
04 Detected that the 3-phase input to the main circuit of the PSM has an open phase.
07 The motor rotates at a speed exceeding 115% (standard setting) of the maximum allowable speed.
09 Temperature of the heat sink of the SPM main circuit has risen to the set value.
10 Input power voltage dropped.
11 PSM detected that the DC link voltage was excessively high.
12 Excessively large current flowed into the DC link of the main circuit.
13 Memory inside the CPU is faulty.
15 Spindle switching operation sequence was not executed correctly.
16 The memory (RAM) is faulty.

RAM in NOVRAM alarm
19 The offset voltage of the phase U current detection circuit is excessively high.
20 The offset voltage of the phase V current detection circuit is excessively high.
24 The power to the CNC is turned off. (This symptom does not represent an error.) Serial communication data transferred between the CNC and spindle amplifier module contains an error.
25 Serial communication between the CNC and spindle amplifier module stopped.
26 The sensor signal (for speed control) for Cs contour control has an error.
27 The sensor signal (position coder signal) for position control is abnormal.
28 The sensor signal (for position control) for Cs contour control is abnormal.
29 An excessive load (standard setting: load meter reading of 9 V) has been applied continuously for a certain period (standard setting: 30 seconds).
30 An excessively large current is detected at the input of the 3-phase main circuit of the PSM.
31 The motor failed to rotate as specified, and has stopped or is rotating at a very low speed.
32 LSI memory for serial communication is abnormal. A check is made when the power is turned on.
33 The PSM could not be charged within a specified time. PSM input has an open phase.
34 Parameter data outside the specifiable range was set.
35 The gear ratio set in a parameter exceeds the value range allowable for internal processing. This alarm is issued with a parameter related to orientation of magnetic sensor type.
36 Error counter overflowed.
37 After emergency stop signal input, the motor is accelerated without being decelerated. This alarm is issued also when the motor is not deactivated (the motor is not decelerated completely) when the acceleration/deceleration time (initial parameter setting: 10 seconds) has elapsed after emergency stop signal input.
39 The position where the one-rotation signal for Cs contour control is generated is incorrect. This alarm is not issued when the parameter indicated below is not set.
40 The one-rotation signal for Cs contour control is not generated.
41 The position where the one-rotation signal of the α position coder, BZ sensor, MZ sensor, α position coder S is incorrect.
42 The one-rotation signal of the α position coder, BZ sensor, MZ sensor, α position coder S is not generated.
43 The position coder signal of the spindle on the mater side used in the differential speed mode is disconnected.
44 An error occurred in the A/D converter.
46 The one-rotation signal of the position coder cannot be detected normally during thread cutting.
47 The count value of α position coder signal pulses is abnormal. The pulse count value of the MZ sensor or BZ sensor is abnormal.
49 In the differential speed mode, the spindle speed on the master side (remote) converted to a motor speed on the slave side (local) exceeded the maximum allowable speed of the motor.
50 A value obtained by internal calculation in spindle synchronization exceeded the allowable range.
51 The PSM detected that the DC link voltage was excessively low.
52 The synchronization signal (ITP) in communication data transferred to and from the CNC stopped.
53 The synchronization signal (ITP) in communication data transferred to and from the CNC stopped.
54 A large current flowing in the motor for a long time was detected.
55 In spindle switching control or output switching control, a mismatch between the switching request signal (SPSL or RSL) and the power line state check signal (MCFN, MFNHG, RCH, or RCHHG) continues during motor activation.
56 Internal cooling circuit faulty.
57 The temperature of the regenerative resistance of the PSM (resistance regenerative type) is excessively high. The PSM is faulty.
58 The temperature of the main circuit-cooling fan of the PSM is abnormally high.
59 The internal cooling fan of the PSM stopped.

Contact our dedicated FANUC repair experts at Tri Star CNC Services, LLC to receive top quality FANUC replacement components or CNC machine repair service for your A06B-6102-H211 SPM-11.

Parts & Repair Warranty Information

Exchange parts and repaired parts include a 1-year warranty. Tri Star CNC, LLC warrants the COMPLETE ASSEMBLY REPAIR – not just the parts and labor.

Get more details on our warranty and please contact us for further support.

Contact Us

For parts repair or replacement, please fill out the form below and we’ll get back to you as soon as possible.

upload pdf

* Indicates a Required Field
Call now for FREE phone support
FREE Phone Support
815-578-9145