SPINDLE AMP

Alarm & error codes

When a FANUC alpha spindle amplifier alarm is thrown chances are you'll need support from professionals experienced in FANUC component repairs. Give us a call - phone support is FREE and we'll clearly define your options for parts repair or replacement:

Alarm Code Alarm Display Description 
8421
1       Red Alarm Light Motor is overheated.
2     Red Alarm Light   Speed is deviated from the command value due to overload and others.
3     Red Alarm Light Red Alarm Light Regenerative circuit is faulty or Fuse F7 in DC link is blown.
4   Red Alarm Light     Fuses F1, F2, or F3 in AC input circuit are blown.
5   Red Alarm Light   Red Alarm Light Fuse AF2 or AF3 on PCB is blown.
6   Red Alarm Light Red Alarm Light   The motor speed exceeds the maximum rated speed (analog system detection).
7   Red Alarm Light Red Alarm Light Red Alarm Light The motor speed exceeds the maximum rated speed (digital system detection).
8 Red Alarm Light       Power voltage (+24 V) is higher than specified.
9 Red Alarm Light     Red Alarm Light Radiator for power semiconductors is overheated.
10 Red Alarm Light   Red Alarm Light   +15 V power voltage is abnormally low.
11 Red Alarm Light   Red Alarm Light Red Alarm Light DC link voltage is abnormally high.
12 Red Alarm Light Red Alarm Light     DC link current is flows excessively.
13 Red Alarm Light Red Alarm Light   Red Alarm Light CPU and peripheral parts are defective.
14 Red Alarm Light Red Alarm Light Red Alarm Light   ROM is defective.
15 Red Alarm Light Red Alarm Light Red Alarm Light Red Alarm Light Option circuit is faulty.

Parts & Repair Warranty Information

Exchange parts and repaired parts include a 1-year warranty. Tri Star CNC, LLC warrants the COMPLETE ASSEMBLY REPAIR – not just the parts and labor.

Get more details on our warranty and please contact us for further support.

Contact Us

For parts repair or replacement, please fill out the form below and we’ll get back to you as soon as possible.

upload pdf

* Indicates a Required Field
Call now for FREE phone support
FREE Phone Support
815-578-9145