LIMITED TIME ONLY for new customers: 15% off your first repair order!

Part Details

A06B-6055-H212#H505 DGTL ACSP M-12

FANUC parts >> A06B-6055-H212#H505 DGTL ACSP M-12

Part Name: DGTL ACSP M-12

Part Number: A06B-6055-H212#H505

Contact Us

For parts repair or replacement, please fill out the form below and we’ll get back to you as soon as possible.

upload pdf

* Indicates a Required Field

Exchange Price

$5550

OUT OF STOCK
Non return of a repairable exchange part within 15 days will result in an additional invoice for the above exchange price.

Repair Price

$3519

Turnaround times for standard repairs are based on workload. Please contact Tri Star CNC services for emergency repair requirements.
Please contact Tri Star CNC Services to place an order.

Digital ACSP M-12 A06B-6055-H212#H505

Production is stopped. Your spindle amplifier is malfunctioning. Every minute spent attempting to fix the problem yourself means valuable dollars lost. You need experienced professionals to help you diagnose and repair the issue in short order. No service repair company is a better choice for you than Tri Star.

We specialize in component level repairs of advanced CNC machinery. Thanks to our vast knowledge of the machinery and our methodical repair process, you are assured we will be able to fix your unit quickly. Our staff has over 90 years of combined experience testing, diagnosing and repairing advanced machinery at a low cost to customers.

Our number one priority at Tri Star is to effectively repair your malfunctioning CNC parts in a timely fashion. Tri Star technicians take the part back to our headquarters in Illinois to test it on a closed loop. Within the confines of our own facility, we can determine the problem with your part safely and efficiently. We do not outsource any of our labor. Everything is done within our home facility.

Once we diagnose the problem and assess the type of repair, we either purchase replacement parts from the original manufacturer or engineer the part ourselves (sometimes the more cost-effective option). Even if we cannot find a problem with your unit, you will only be charged with a small clean and test fee.

Trust in the repair professionals at Tri Star, and you will get the best technicians on the market at an affordable price.

Error codes & alarms

When a FANUC spindle amp alarm is thrown chances are you'll need support from professionals experienced in FANUC component repairs. Give us a call - phone support is FREE and we'll clearly define your options for parts repair or replacement:

Alarm CodeDescription
01 Spindle motor over temp
02 Actual motor speed is largely deviated from the commanded speed.
03 DC link fuse has blown
04 Detected that the 3-phase input to the main circuit of the PSM has an open phase.
07 The motor rotates at a speed exceeding 115% (standard setting) of the maximum allowable speed.
09 Temperature of the heat sink of the SPM main circuit has risen to the set value.
10 Input power voltage dropped.
11 PSM detected that the DC link voltage was excessively high.
12 Excessively large current flowed into the DC link of the main circuit.
13 Memory inside the CPU is faulty.
15 Spindle switching operation sequence was not executed correctly.
16 The memory (RAM) is faulty.
17 NVRAM is faulty.
19 The offset voltage of the phase U current detection circuit is excessively high.
20 The offset voltage of the phase V current detection circuit is excessively high.
24 The power to the CNC is turned off. (This symptom does not represent an error.) Serial communication data transferred between the CNC and spindle amplifier module contains an error.
25 Serial communication between the CNC and spindle amplifier module stopped.
26 The sensor signal (for speed control) for Cs contour control has an error.
27 The sensor signal (position coder signal) for position control is abnormal.
28 The sensor signal (for position control) for Cs contour control is abnormal.
29 An excessive load (standard setting: load meter reading of 9 V) has been applied continuously for a certain period (standard setting: 30 seconds).
30 An excessively large current is detected at the input of the 3-phase main circuit of the PSM.
31 The motor failed to rotate as specified, and has stopped or is rotating at a very low speed.
32 LSI memory for serial communication is abnormal. A check is made when the power is turned on.
33 The PSM could not be charged within a specified time. PSM input has an open phase.
34 Parameter data outside the specifiable range was set.
35 The gear ratio set in a parameter exceeds the value range allowable for internal processing. This alarm is issued with a parameter related to orientation of magnetic sensor type.
36 Error counter overflowed.
37 After emergency stop signal input, the motor is accelerated without being decelerated. This alarm is issued also when the motor is not deactivated (the motor is not decelerated completely) when the acceleration/deceleration time (initial parameter setting: 10 seconds) has elapsed after emergency stop signal input.
39 The position where the one-rotation signal for Cs contour control is generated is incorrect. This alarm is not issued when the parameter indicated below is not set.
40 The one-rotation signal for Cs contour control is not generated.
41 The position where the one-rotation signal of the α position coder, BZ sensor, MZ sensor, α position coder S is incorrect.
47 The count value of α position coder signal pulses is abnormal. The pulse count value of the MZ sensor or BZ sensor is abnormal.

Contact the professional Illinois service technicians at Tri Star for your CNC machinery repair needs.

Parts & Repair Warranty Information

Exchange parts and repaired parts include a 1-year warranty. Tri Star CNC, LLC warrants the COMPLETE ASSEMBLY REPAIR – not just the parts and labor.

Get more details on our warranty and please contact us for further support.

Contact Us

For parts repair or replacement, please fill out the form below and we’ll get back to you as soon as possible.

upload pdf

* Indicates a Required Field
Call now for FREE phone support
FREE Phone Support
815-578-9145