SPINDLE AMP - AC DIGITAL A06B-6055-H212

When you are having issues with a spindle amp, you can't afford to waste precious production time on anything but the best CNC machining repair services. Every minute spent lost in downtime means dollars lost. With 90 years of collective experience repairing spindles and GE FANUC, the repair technicians at Tri Star will get you back up and running in the least amount of time possible.

Our CNC FANUC repair experts do not outsource any labor to outside sources. When we determine the malfunctioning part, we take it back to our headquarters in McHenry, Illinois and test the part on a closed loop control system. The Tri Star technicians diagnose the problem, run through their progressions and repair the problem as quickly as possible. If for some reason we cannot find the part at fault, we only charge you a small clean and test fee.

If a replacement part is not available from the original manufacturer, we engineer our own FANUC replacement parts. Depending on the part, engineering the part on our own may actually cost less than purchasing an original part from a limited stock.

No other CNC machine repair company in the Midwest provides more timely and efficient maintenance services. Trust in our technicians to diagnose and repair your CNC equipment and get your production line humming once again.

Error codes & alarms

When a FANUC spindle amp alarm is thrown chances are you'll need support from professionals experienced in FANUC component repairs. Give us a call - phone support is FREE and we'll clearly define your options for parts repair or replacement:

Alarm CodeDescription
01 Spindle motor over temp
02 Actual motor speed is largely deviated from the commanded speed.
03 DC link fuse has blown
04 Detected that the 3-phase input to the main circuit of the PSM has an open phase.
07 The motor rotates at a speed exceeding 115% (standard setting) of the maximum allowable speed.
09 Temperature of the heat sink of the SPM main circuit has risen to the set value.
10 Input power voltage dropped.
11 PSM detected that the DC link voltage was excessively high.
12 Excessively large current flowed into the DC link of the main circuit.
13 Memory inside the CPU is faulty.
15 Spindle switching operation sequence was not executed correctly.
16 The memory (RAM) is faulty.
17 NVRAM is faulty.
19 The offset voltage of the phase U current detection circuit is excessively high.
20 The offset voltage of the phase V current detection circuit is excessively high.
24 The power to the CNC is turned off. (This symptom does not represent an error.) Serial communication data transferred between the CNC and spindle amplifier module contains an error.
25 Serial communication between the CNC and spindle amplifier module stopped.
26 The sensor signal (for speed control) for Cs contour control has an error.
27 The sensor signal (position coder signal) for position control is abnormal.
28 The sensor signal (for position control) for Cs contour control is abnormal.
29 An excessive load (standard setting: load meter reading of 9 V) has been applied continuously for a certain period (standard setting: 30 seconds).
30 An excessively large current is detected at the input of the 3-phase main circuit of the PSM.
31 The motor failed to rotate as specified, and has stopped or is rotating at a very low speed.
32 LSI memory for serial communication is abnormal. A check is made when the power is turned on.
33 The PSM could not be charged within a specified time. PSM input has an open phase.
34 Parameter data outside the specifiable range was set.
35 The gear ratio set in a parameter exceeds the value range allowable for internal processing. This alarm is issued with a parameter related to orientation of magnetic sensor type.
36 Error counter overflowed.
37 After emergency stop signal input, the motor is accelerated without being decelerated. This alarm is issued also when the motor is not deactivated (the motor is not decelerated completely) when the acceleration/deceleration time (initial parameter setting: 10 seconds) has elapsed after emergency stop signal input.
39 The position where the one-rotation signal for Cs contour control is generated is incorrect. This alarm is not issued when the parameter indicated below is not set.
40 The one-rotation signal for Cs contour control is not generated.
41 The position where the one-rotation signal of the α position coder, BZ sensor, MZ sensor, α position coder S is incorrect.
47 The count value of α position coder signal pulses is abnormal. The pulse count value of the MZ sensor or BZ sensor is abnormal.

Call or email our service repair professionals for more information about the spindle amp #A06B-6055-H212 today.

Parts & Repair Warranty Information

Exchange parts and repaired parts include a 1-year warranty. Tri Star CNC, LLC warrants the COMPLETE ASSEMBLY REPAIR – not just the parts and labor.

Get more details on our warranty and please contact us for further support.

Contact Us

For parts repair or replacement, please fill out the form below and we’ll get back to you as soon as possible.

upload pdf

* Indicates a Required Field
Call now for FREE phone support
FREE Phone Support
815-578-9145